- Cycle life: ≥ 3,000 cycles to 70% capacity at 1C/1C; ≥ 1,000 cycles to 70% at 3C/3C (25 °C).
- Matched sets: shipped in batches with capacity ≤ 0.5 Ah, ACR ≤ 0.6 mΩ and voltage ≤ 5 mV spread.
- Safety program: external short (20 mΩ/60 min), 130 °C thermal soak, crush, drop and low pressure — no explosion, no fire.
- Standards: GB 38031 / GB 43854 aligned; UN 38.3 transport, RoHS compliant.
Data sheet
| Item | IBR46120PC · specification |
|---|---|
| Chemistry | LiFePO4 / graphite (low-temperature high-rate system) |
| Format | Ø46.35 ± 0.30 mm × 120.50 ± 0.50 mm, full-tab (tabless) winding |
| Nominal capacity | ≥ 20.0 Ah @0.33C (≥ 19.6 Ah @0.5C), 25 °C |
| Nominal voltage | 3.23 V @0.33C (3.20 V @0.5C, 3.17 V @1C) |
| Energy density | ≈ 140 Wh/kg (460 g ± 10 g cell weight) |
| Charge voltage / cut-off | 3.650 ± 0.005 V; cut-off current 0.02C |
| Discharge cut-off | 2.5 V (T > 0 °C); 2.0 V (T ≤ 0 °C) |
| Standard charge / discharge | 0.20C / 0.50C |
| Max continuous charge | 3.0C @25 °C |
| Max continuous discharge | 6.0C @25 °C |
| Max pulse discharge | 10.0C for 10 s |
| AC internal resistance | ≤ 0.6 mΩ (1 kHz, 30% SOC) |
| DC internal resistance | ≤ 2.5 mΩ (30% SOC, 6C discharge 10 s) |
| Temperature range | Charge 0 °C to 45 °C; discharge −20 °C to 55 °C |
| Low-temperature discharge | ≥ 70% @−20 °C · ≥ 80% @−10 °C · ≥ 85% @0 °C · ≥ 95% @55 °C (0.5C) |
| Cycle life | ≥ 3,000 cycles to 70% capacity (1C/1C, 25 °C); ≥ 1,000 cycles to 70% at 3C/3C |
| Self-discharge | ≤ 3% per month |
| Storage | 0–45 °C (≤ 3 months); 0–25 °C (> 3 months); ≤ 70% RH |
| Transport voltage | 3.2–3.3 V (30% SOC), shipped at ≈ 30% SOC |
| Terminals | Thermoelectric separation design — both terminals welded on top; bottom welding prohibited |
| Safety tests passed | Over-charge (1.5×), over-discharge, external short, 130 °C thermal test, crush (100 kN), 1.5 m drop, low pressure — no explosion, no fire |
| Standards | GB 38031 / GB 43854 · UN 38.3 · RoHS; production under ISO 9001 |
Engineering notes
Built for Duty Cycles That Never Stop
- Fast Opportunity Charging. With 3C continuous charging capability, a 20-minute charging window can replenish approximately 70–80% of capacity, helping maximize equipment uptime.
- Reliable Cold-Weather Performance. Specified discharge performance down to −20 °C, supported by laboratory-characterized charging behaviour under low-temperature conditions.
- Consistent Cell Matching. Batch consistency within ≤ 0.5 Ah capacity variation and ≤ 5 mV voltage variation helps maintain balance and reliability across large series-connected battery configurations.
- Shipment-Ready Compliance. Every shipment leaves at approximately 30% SOC, accompanied by UN 38.3 transport test documentation and MSDS/SDS.
Next Step
Get a Sample Plan for Your Application
Share your battery pack configuration, duty cycle and operating environment with us. Our team will respond with the relevant technical data package, sample availability and an application-specific test plan.