Skip to content
IEC 62619UN 38.3ISO 9001GB 38031
Home Products IER4695PC

IER4695PC — 37 Ah

Measured rate charge test of IER4695PC at 1C to 6C: voltage and surface temperature versus state of charge
Measured rate discharge test of IER4695PC at 1C to 6C: voltage and surface temperature versus state of charge
Measured discharge curves of IER4695PC at 25, -20, -30 and -40 degrees C
  • Rate capability: ≥ 95% of rated capacity at 1C, ≥ 90% at 3C (25 °C).
  • Fast-charge tested: 2C charge to 4.20 V completed within 30 minutes with ≥ 80% of calibrated capacity.
  • Cold discharge: ≥ 85% at 0 °C, ≥ 80% at −10 °C, ≥ 70% at −20 °C (0.33C to 2.0 V).
  • Thermal margin: over-current paths dimensioned at 3 A/mm² (Al) and 5 A/mm² (Cu) to keep temperature rise ≤ 40 °C.
Data sheet
ItemIER4695PC · specification
ChemistryNMC / graphite (ternary ultra-fast-charge system)
FormatØ46.35 ± 0.30 mm × 97.50 ± 0.50 mm, full-tab (tabless) winding
Nominal capacity≥ 37.0 Ah @0.33C discharge, 25 °C
Nominal voltage3.53 V @0.33C (3.50 V @0.5C, 3.47 V @1C)
Energy density≈ 326 Wh/kg (400 g ± 10 g cell weight)
Charge voltage / cut-off4.200 ± 0.005 V; cut-off current 0.05C
Discharge cut-off2.5 V (T > 0 °C); 2.0 V (T ≤ 0 °C)
Standard charge / discharge0.33C / 0.33C
Max continuous charge4.0C @25 °C (SOC 10–45%)
Max continuous discharge6.0C @25 °C
Max pulse discharge10.0C for 30 s
AC internal resistance≤ 1.0 mΩ (1 kHz, 30% SOC)
DC internal resistance≤ 3.0 mΩ (30% SOC, 2C discharge 10 s)
Temperature rangeCharge 0 °C to 45 °C; discharge −20 °C to 55 °C
Low-temperature discharge≥ 70% @−20 °C · ≥ 80% @−10 °C · ≥ 85% @0 °C · ≥ 95% @45 °C (0.33C)
Cycle life≥ 400 cycles to 80% capacity (1C charge 4.18 V / 1C discharge 2.8 V, 25 °C)
Self-discharge≤ 3% per month
Storage0–45 °C (≤ 3 months); 0–25 °C (> 3 months); ≤ 70% RH
Transport voltage3.00–3.50 V (10–30% SOC), shipped at ≈ 30% SOC
TerminalsThermoelectric separation design — both terminals welded on top; bottom welding prohibited
Safety tests passedOver-charge, over-discharge, crush (100 kN), temperature cycling (−40 °C to 85 °C), 1.5 m drop, low pressure (11.6 kPa) — no explosion, no fire
CertificationIEC 62619 · UN 38.3 · RoHS; production under ISO 9001
Engineering notes

Designed for Integration, Not Just Procurement

  • Thermal & Electrical Pathway Separation. Current flow and heat dissipation follow separate paths, with both positive and negative terminals accessible from the top cap, eliminating the need for bottom-side welding.
  • Intelligent Charging Management. The BMS should follow the cell-specific SOC and temperature charging profiles. Continuous charging above 148 A is not recommended.
  • Robust Mechanical Design. The cell casing is designed to withstand internal pressures of 5–10 MPa. Its cylindrical geometry provides structural stability and supports compact, space-efficient module configurations.
  • Shipment-Ready Compliance. Cells are shipped at approximately 30% SOC, with UN 38.3 test documentation and MSDS/SDS provided with each shipment.
Automated assembly line producing 46 mm full-tab cells
Next Step

Get a Sample Plan for Your Application