- Rate capability: ≥ 95% of rated capacity at 1C, ≥ 90% at 3C (25 °C).
- Fast-charge tested: 2C charge to 4.20 V completed within 30 minutes with ≥ 80% of calibrated capacity.
- Cold discharge: ≥ 85% at 0 °C, ≥ 80% at −10 °C, ≥ 70% at −20 °C (0.33C to 2.0 V).
- Thermal margin: over-current paths dimensioned at 3 A/mm² (Al) and 5 A/mm² (Cu) to keep temperature rise ≤ 40 °C.
Data sheet
| Item | IER4695PC · specification |
|---|---|
| Chemistry | NMC / graphite (ternary ultra-fast-charge system) |
| Format | Ø46.35 ± 0.30 mm × 97.50 ± 0.50 mm, full-tab (tabless) winding |
| Nominal capacity | ≥ 37.0 Ah @0.33C discharge, 25 °C |
| Nominal voltage | 3.53 V @0.33C (3.50 V @0.5C, 3.47 V @1C) |
| Energy density | ≈ 326 Wh/kg (400 g ± 10 g cell weight) |
| Charge voltage / cut-off | 4.200 ± 0.005 V; cut-off current 0.05C |
| Discharge cut-off | 2.5 V (T > 0 °C); 2.0 V (T ≤ 0 °C) |
| Standard charge / discharge | 0.33C / 0.33C |
| Max continuous charge | 4.0C @25 °C (SOC 10–45%) |
| Max continuous discharge | 6.0C @25 °C |
| Max pulse discharge | 10.0C for 30 s |
| AC internal resistance | ≤ 1.0 mΩ (1 kHz, 30% SOC) |
| DC internal resistance | ≤ 3.0 mΩ (30% SOC, 2C discharge 10 s) |
| Temperature range | Charge 0 °C to 45 °C; discharge −20 °C to 55 °C |
| Low-temperature discharge | ≥ 70% @−20 °C · ≥ 80% @−10 °C · ≥ 85% @0 °C · ≥ 95% @45 °C (0.33C) |
| Cycle life | ≥ 400 cycles to 80% capacity (1C charge 4.18 V / 1C discharge 2.8 V, 25 °C) |
| Self-discharge | ≤ 3% per month |
| Storage | 0–45 °C (≤ 3 months); 0–25 °C (> 3 months); ≤ 70% RH |
| Transport voltage | 3.00–3.50 V (10–30% SOC), shipped at ≈ 30% SOC |
| Terminals | Thermoelectric separation design — both terminals welded on top; bottom welding prohibited |
| Safety tests passed | Over-charge, over-discharge, crush (100 kN), temperature cycling (−40 °C to 85 °C), 1.5 m drop, low pressure (11.6 kPa) — no explosion, no fire |
| Certification | IEC 62619 · UN 38.3 · RoHS; production under ISO 9001 |
Engineering notes
Designed for Integration, Not Just Procurement
- Thermal & Electrical Pathway Separation. Current flow and heat dissipation follow separate paths, with both positive and negative terminals accessible from the top cap, eliminating the need for bottom-side welding.
- Intelligent Charging Management. The BMS should follow the cell-specific SOC and temperature charging profiles. Continuous charging above 148 A is not recommended.
- Robust Mechanical Design. The cell casing is designed to withstand internal pressures of 5–10 MPa. Its cylindrical geometry provides structural stability and supports compact, space-efficient module configurations.
- Shipment-Ready Compliance. Cells are shipped at approximately 30% SOC, with UN 38.3 test documentation and MSDS/SDS provided with each shipment.